SPECIFICATIONS CHART

PHYSICAL CHARACTERISTICS
Dimensions 7.34 in. H x 4.82 in. W x 2.93 in. D 18.65 cm H x 12.25 cm W x 7.43 cm D
Weight (w/o cable) Weight (w/o cable) 12.56 oz./356 g
Power Requirements 4.5 – 14 VDC
Stand-by Current 50 mA
Power Sources Depending on host: • Host power • External power supply
Colour Twilight Black/Yellow
PERFORMANCE CHARACTERISTICS
Scanner type Retrocollective
Light source 650 nm visible laser diode
Scan repetition 36 scans per second typical
Minimum element width 7.5 mil (0.191 mm)
Nominal working distance See decode zone
Print contrast 25% minimum reflective difference
Roll (Tilt)1 +/- 10 degrees from normal
Pitch2 +/- 65 degrees from normal
Skew (Yaw)3 +/- 60 degrees from normal
Decode capability UPC/EAN, UPC/EAN with Supplementals, GS1-128 (formerly UCC/EAN 128), JAN 8 & 13, Code 39, Code 39 Full ASCII, Code 39 Trioptic, Code 128, Code 128 Full ASCII, Codabar (NW7), Interleaved 2 of 5, Discrete 2 of 5, Code 93, MSI, Code 11, Code 32, Bookland EAN, IATA, GS1DataBar (formerly RSS)
Interfaces supported RS232, Keyboard Wedge, Wand Emulation, Scanner Emulation, IBM 468X/469X, USB and Synapse
USER ENVIRONMENT
Operating Temp. -22° to 122° F/-30° to 50° C
Storage temperature -40˚ to 158˚F (-40˚ to 70˚C)
Humidity 5% to 95% relative humidity, noncondensing
Sealing Sealed to IP65 specifications
Drop specifications Unit functions normally after 50 drops to concrete from 6.5 ft. (2m)
Ambient lighting tolerance Tolerant to typical artificial indoor and natural outdoor (direct sunlight) lighting conditions. Fluorescent, Incandescent, Mercury Vapor, Sodium Vapor, LED4: 450 Ft Candles (4,844 Lux) Sunlight: 8000 Ft Candles (43,040 Lux)
Electrostatic discharge Conforms to 20 kV air discharge and 8 kV of contact discharge
REGULATORY
Input transient protection IEC 1000-4-(2,3,4,5,6,11)
EMI/RFI FCC Part 15 Class B, ICES-003 Class B, European Union EMC Directive, Japan VCCI/MITI/Dentori